2018 Vol.38, Issue 5 Preview Page

Research Article

30 October 2018. pp. 27-36
Abstract
References
1
Spitler, J. D. and Fisher, D. E., Development of Periodic Response Factors for Use with the Radiant Time Series Method, ASHRAE Transactions, Vol. 105, Part 2, SE-99-1-1, 1999.
2
Spitler, J. D. and Fisher, D. E., On the Relationship between the Radiant Time Series and Tranfer Function Methods for Design Cooling Load Calculations, International Journal of Heating, Ventilating, Air-Conditioning and Refrigerating Research, Vol. 5, pp. 125-138, 1999.
3
Wang, S. and Chen, Y., A Simple Procedure for Calculating Thermal Response Factors and Conduction Transfer Functions of Multilayer Walls, Applied Thermal Engineering, Vol. 1, No. 22, pp. 333-338, 2002.
10.1016/S1359-4311(01)00086-2
4
Mitalas, G. P. and Stephenson, D. G., Cooling Load Calculation by Thermal Response Factor, ASHRAE Transactions, Vol. 73, Part 2, III 2.1-2.10, 1967.
5
Ouyang, K. and Haghighat, F., A Procedure for Calculating Thermal Response Factors of Multilayer Walls-state-space Method, Buling Environment, Vol. 26, No. 2, pp. 173-177, 1991.
10.1016/0360-1323(91)90024-6
6
Davies, M. G., Wall Transient Heat Flow Using Time Domain Analysis, Building Environment, Vol. 32, No. 5, pp. 427-446, 1997.
10.1016/S0360-1323(97)00007-3
7
Spitler, J. D. and Nigusse, B. A., Refinements and Improvements to the Radiant Time Series Method, ASHRAE Transactions, Vol. 116, Part 1, pp. 542-599, OR-10-057, 2010.
8
Nigusse, B., Improvements to the Radiant Time Series Method Cooling Load Calculation Procedure, Oklahoma State University, 2007.
9
Byun, K. H., A Procedure for Computing Conduction Time Series Factors by Numerical Method. J. of Korean Solar Energy Society, Vol. 37, No. 5, pp. 77-84, 2017.
10
Incropera, F. P., Bergman, T. L, and Lavine, A. S., Foundations of Heat Transfer, John Wiley & Sons, Inc., 2013.
11
Byun, K. H., The Analysis of Green Roof During the Summer by Numerical Method, J. of the Korean Solar Energy Society, Vol. 36, No. 5, pp. 51-61, 2016.
10.7836/kses.2016.36.5.051
12
Byun, K. H., Simulation of Thin Green Roof for Summer in Seoul, Int. J. of Air-conditioning and Refrigeration,
10.1142/S201032517500341, 25(4), 2017.
13
ASHRAE Fundamentals Handbook, ASHRAE, 2005 and 2013.
Information
  • Publisher :Korean Solar Energy Society
  • Publisher(Ko) :한국태양에너지학회
  • Journal Title :Journal of the Korean Solar Energy Society
  • Journal Title(Ko) :한국태양에너지학회 논문집
  • Volume : 38
  • No :5
  • Pages :27-36
  • Received Date : 2018-07-02
  • Revised Date : 2018-09-07
  • Accepted Date : 2018-10-30