All Issue

2026 Vol.46, Issue 1 Preview Page

Research Article

28 February 2026. pp. 15-24
Abstract
References
1

The INSIGHT Partners, Recirculating Aquaculture Systems Market Size to Surpass USD 9.04 Billion by 2031, 2025. https://www.globenewswire.com/news-release/2025/05/12/3079228/0/en/Recirculating-Aquaculture-Systems-Market-Size-to-Surpass-USD-9-04-Billion-by-2031-The-Insight-Partners.html. last accessed on the 22nd October 2025.

2

Martins, C., Eding, E., Verdegem, M., Heinsbroek, L., Schneider, O., Blancheton, J., Roque d’Orbcastel, E., and Verreth, J., New Developments in Recirculating Aquaculture Systems in Europe: A Perspective on Environmental Sustainability, Aquacultural Engineering, Vol. 43, No. 3, pp. 83-93, 2010, https://doi.org/10.1016/j.aquaeng.2010.09.002.

10.1016/j.aquaeng.2010.09.002
3

Ayuso-Virgili, G., Jafari, L., Lande-Sudall, D., and Lǖmmen, N., Linear Modelling of the Mass Balance and Energy Demand for a Recirculating Aquaculture System, Aquacultural Engineering, Vol. 101, No. 102330, 2023, https://doi.org/10.1016/j.aquaeng.2023.102330.

10.1016/j.aquaeng.2023.102330
4

Zhang, R., Chen, T., Wang, Y., and Short, M., An Optimisation Approach for the Design and Operation of Recirculating Aquaculture Systems Integrated with Sustainable Hybrid Energy Systems, Journal of Cleaner Production, Vol. 477, No. 143860, 2024, https://doi.org/10.1016/j.jclepro.2024.143860.

10.1016/j.jclepro.2024.143860
5

Goo, J., Kwak, Y., Shin, H., Kim, J., Jo, S., and Huh, J., Feasibility Study of Dynamic Thermal-Modeling Development Using Measurement and Validation: Case Study of Indoor Fish Farm, Applied Thermal Engineering, Vol. 228, No. 120512, 2023, https://doi.org/10.1016/j.applthermaleng.2023.120512.

10.1016/j.applthermaleng.2023.120512
6

Ribeiro, E., Jorge, H., and Quintela, D., HVAC System Energy Optimization in Indoor Swimming Pools, BauSIM, pp. 385-390, September 2010, Vienna, Austria, https://publications.ibpsa.org/conference/paper/?id=bausim2010_385.

7

Ribeiro, E., Jorge, H., and Quintela, D., An Approach to Optimised Control of HVAC Systems in Indoor Swimming Pools, International Journal of Sustainable Energy, Vol. 35, No. 4, pp. 378-395, 2014, https://doi.org/10.1080/14786451.2014.907293

10.1080/14786451.2014.907293
8

ASHRAE, ASHRAE Guideline 14-2014: Measurement of Energy, Demand, and Water Savings, Atlanta, GA, USA, 2014.

Information
  • Publisher :Korean Solar Energy Society
  • Publisher(Ko) :한국태양에너지학회
  • Journal Title :Journal of the Korean Solar Energy Society
  • Journal Title(Ko) :한국태양에너지학회 논문집
  • Volume : 46
  • No :1
  • Pages :15-24
  • Received Date : 2025-11-01
  • Revised Date : 2025-12-31
  • Accepted Date : 2026-01-04