Research Article
Korea Energy Agency, 2024 KEA Energy Handbook, 2024. https://www.energy.or.kr/energy_issue/mail_vol240/pdf/2024_KEA_02.pdf. last accessed on the 14th March 2025.
Choi, H. U., Fatkhur, R., Kim, Y. B., Yoon, J. I., Son, C. H., and Choi, K. H., CFD Analysis on the Heat Transfer Performance with Various Obstacles in Air Channel of Air-Type PV/Thermal Module, Journal of the Korean Solar Energy Society, Vol. 38, No. 1, pp. 33-43, 2018, https://doi.org/10.7836/kses.2018.38.2.033.
10.7836/kses.2018.38.2.033Ahn, S. Y. and Kim, K. Y., Effects of Y-shaped Ribs on Heat Transfer Performance and Pressure Drop of a Solar Air Heater, Trans. Korean Soc. Mech. Eng. B, Vol. 45, No. 4, pp. 225-235, 2021, https://doi.org/10.3795/KSME-B.2021.45.4.225.
10.3795/KSME-B.2021.45.4.225Lee, T. J., Jeong, H. J., and Shin, D. H., Optimization of the Rib-Fin Shape of Solar Air Heater by CFD, KSME, pp. 383-388, November 2021, Gwangju, Republic of Korea.
Yu, J. S., Lee, K. S.,Kim, J. H., and Kim, J. T., Study on Electrical and Thermal Performance Assessment of Air-Type PVT Collector with Perforated Baffle, Journal of the Korean Solar Energy Society, Vol. 41, No. 1, pp. 25-34, 2021, https://doi.org/10.7836/kses.2021.41.1.025.
10.7836/kses.2021.41.1.025Singh, S., Singh, B., Hans, V. S., and Gill, R. S., CFD (Computational Fluid Dynamics) Investigation on Nusselt Number and Friction Factor of Solar Air Heater Duct Roughened with Non-Uniform Cross-Section Transvers Rib, Energy, Vol. 84, pp. 509-517, 2015, https://doi.org/10.1016/j.energy.2015.03.015.
10.1016/j.energy.2015.03.015Thakur, D., S., Khan, M., K., and Pathak, M., Performance Evaluation of Solar Air Heater with Novel Hyperbolic Rib Geometry, Renewable Energy, Vol. 105, pp. 786-797, 2017, https://doi.org/10.1016/j.renene.2016.12.092.
10.1016/j.renene.2016.12.092Sivakandhan, C., Arjunan, T. V., and Matheswaran, M. M., Thermohydraulic Performance Enhancement of a New Hybrid Duct Solar Air Heater with Inclined Rib Roughness, Renewable Energy, Vol. 147, Part 1, pp. 2345-2357, 2020, https://doi.org/10.1016/j.renene.2019.10.007.
10.1016/j.renene.2019.10.007Alam, T., Development of Correlations of Nusselt Number and Friction Factor of Solar Thermal Collector Equipped with Hybrid Rib Roughness, Solar Energy Materials and Solar Cells, Vol. 272, 112887, 2024, https://doi.org/10.1016/j.solmat.2024.112887.
10.1016/j.solmat.2024.112887Choi, H. U., Kim, Y. B., Yoon, J. I., Son, C. H., and Choi, K. H., Research on the Heat Transfer and Pressure Drop by Installation Conditions of Rectangular Obstacle in a Solar Air Heater Based on CFD, Journal of the Korean Solar Energy Society, Vol. 39, No. 1, pp. 77-89, 2019, https://doi.org/10.7836/kses.2019.39.1.077.
10.7836/kses.2019.39.1.077Mahanand, Y. and Senapati, H. R., Thermo-hydraulic Performance Analysis of a Solar Air Heater (SAH) with Quarter-circular Ribs on The Absorber Plate A Comparative Study, International Journal of Thermal Sciences, Vol. 161, 106747, 2021, https://doi.org/10.1016/j.ijthermalsci.2020.106747.
10.1016/j.ijthermalsci.2020.106747Webb, R. L. and Gee, D. L., Forced Convection Heat Transfer in Helically Rib-roughened Tubes, International Journal of Heat and Mass Transfer, Vol. 23, No. 8, pp. 1127-1136, 1980, https://doi.org/10.1016/0017-9310(80)90177-5.
10.1016/0017-9310(80)90177-5Alam, T., Saini, R. P., and Saini, J. S., Experimental Investigation on Heat Transfer Enhancement Due to V-shaped Perforated Blocks in a Rectangular Duct of Solar Air Heater, Energy Conversion and Management, Vol. 81, pp. 374-383, 2014, https://doi.org/10.1016/j.enconman.2014.02.044.
10.1016/j.enconman.2014.02.044- Publisher :Korean Solar Energy Society
- Publisher(Ko) :한국태양에너지학회
- Journal Title :Journal of the Korean Solar Energy Society
- Journal Title(Ko) :한국태양에너지학회 논문집
- Volume : 45
- No :3
- Pages :47-59
- Received Date : 2025-03-18
- Revised Date : 2025-04-24
- Accepted Date : 2025-04-24
- DOI :https://doi.org/10.7836/kses.2025.45.3.047


Journal of the Korean Solar Energy Society