All Issue

2017 Vol.37, Issue 4
August 2017. pp. 1-11
Abstract
References
1
Kang, G. H. and  Kim, K. H., Photovoltaic Module, Sungandang, 2012.
2
Lee, J. S. and Kim, K. H., Solar Cell Engineering, Green, 2007.
3
Bruckman, LS., Wheeler, NR., Ma, J., Wang, E., Wang, C. K., Chou, I., Sun, J., and French, R. H, Statical and Domain Analytics Applied to PV module Lifetime and Degradation Science, IEEE Acces, Vol. 1, pp. 384-403, 2013.
4
Sharma, V. and Chandel, S. S., Performance and Degradation Analysis for Long Term Reliality of Solar Photovoltaic Systems: A review, Renewable and Sustainable Energy Reiviews, Vol. 27, pp. 753-767, 2013.
5
Jung, T. H., Go, J. W., Kang, G. H., and Ahn, H. K., Output Characteristics of PV module Considering Partially Reverse Biased Conditions, Solar Energy, Vol. 92, pp. 214-200, 2013.
6
Carmen Alonso-Garcia, M., and Ruiz, J. M., Analysis and Modelling the Reverse Characteristic of Photovoltaic Cells, Solar Energy Materials and Solar Cells, Vol. 90, pp. 1105-1120, 2006.
7
Herrmann, W., Adrian, M., and Wiesner, W., Operational Behavior of Commercial Solar Cells under Reverse Biased Conditions, Proceedings of the 2nd World Conference on PVSEC, pp. 2357-2359, Vienna, 1988.
8
Potnuru, S. R., Pattabiraman. D., Ganesan, S. I., Chiilakapati, N., Positioning of PV panels for Reducition in Line Loss and Mismatch Losses in PV array, Renewable Energy, Vol. 78, pp. 264-275. 2015.
9
Wang, Y. and Hsu, P., An Investigation on Partial Shading of PV modules with Different Connection Configuration of PV cells, Energy, Vol. 35, pp. 3069-6078, 2011.
10
Bauwens, P. and Doutreloigne, J., Reducing Partial Shading Power Loss with an Intergrated Smart Bypass, Solar Energy, Vol. 103, pp. 134-142, 2014.
11
Shin, W. G., Go, S. H., Ju, Y. C., Chang, H. S., and Kang, G. H., Estimation of Output Power for PV module with Damaged Bypass Diode using MATLAB, KSES, Vol. 36, pp. 63-71, 2016.
12
Go, S. H., Ju, Y. C., Hwang, H. M., So, J. H., Jung, Y. S., Song, H. J., Song, H. E., Kim, K. S., and Kang, G. H., Electric and Thermal Characteristics of Photovoltaic Module under Partial Shading and with a Damaged bypass Diode, Energy, Vol. 128, pp. 232-243, 2017.
13
Silverstre, S., Boronat, A., and Chuoder, A., Study of Bypass Diodes Configuration on PV Modules, Applied Energy, Vol. 86, pp. 1632-1640, 2009.
Information
  • Publisher :Korean Solar Energy Society
  • Publisher(Ko) :한국태양에너지학회
  • Journal Title :Journal of the Korean Solar Energy Society
  • Journal Title(Ko) :한국태양에너지학회 논문집
  • Volume : 37
  • No :4
  • Pages :1-11
  • Received Date : 2017-04-17
  • Revised Date : 2017-08-21
  • Accepted Date : 2017-08-28