All Issue

2016 Vol.36, Issue 5 Preview Page
October 2016. pp. 31-50
Abstract
References
1
Arbel, Avraham, Barak, M., and Shklyar, A., Combination of Forced Ventilation and Fogging Systems for Cooling Greenhouses, Article in Biosystems Engineering Vol. 84, No. 1, pp. 45-55, 2003.
2
Kim, M. K., Kim, K. S., and Kwon, H. J., The Cooling Effect of Fog Cooling System as Affected by Air Exchange Rate in Natural Ventilation Greenhouse. The Korean Society for Bio_Environment Control. Journal of environment Control, Vol. 10, No. 1, pp. 10-14, 2001.
3
Kim, J. H., Kim, C. S., Koo, K. H., and Lee, K. M., A Fundamental Study for the Automatic Control System in Greenhouse Using Microcomputer(III) -A variation of temperature and humidity by the window opening ways of the even-Span type house-. Korean Society for Agricultural Machinery. Journal of Biosystems Engineering, Vol. 20, No. 2, pp. 162-172, 1995.
4
Min, Y. B. et al. Cooling Control of Greenhouse Using Roof Window Ventilation by Simple Fuzzy Algorithm. Institute of Agriculture & Life Science, Gyeongsang National University. Journal of Agriculture & Life Science. Vol. 44, No. 4. pp. 69-77, 2010 (In korean).
5
Handarto Handarto, Makio Hayashi, Katsumi Ohyama and Kozai, T., Developing control logic for a highpressure fog cooling system operation for a naturally ventilated greenhouse, Environmental Control in Biology Vol. 44, No. 1, pp. 1-9, 2006.
6
Kim, Y. B., Sung, H. S., Yun, N. K., Lee, S. Y., Hwang, S. J., Kim, H. T., and Lee, J. P., Effects of the Open Level of the Side Window on the Control of the Temperature and Relative Humidity in the Fog Cooling Greenhouse, Vol. 45, No. 6, pp. 265-278, 2011.
7
Shin, I. H., Kang, H. G., Lee, S. D., and Yoo, H. C., Analysis of the ventilation for natural air-conditioning (free cooling), Journal of the Korean Solar Energy Society, Vol. 2010, No. 11, pp. 363-368.
8
Kim, S. J. and Na, S. Y., A Case Study on the Energy Conservation Design Strategies of the Multipurpose Greenhouse, Journal of the Korean Solar Energy Society, Vol. 26, No. 4, pp.101-107, 2006.
9
Agmail, Waleed Ibrahim Ramadan, Raphael, Linker and Avraham, Arbel, Robust H-infinity Control of Greenhouse Ventilation and Fogging, Conference Paper of ASABE, Paper No. 096100, January 2009.
10
Suhardiyanto, Herry and Romdhonah, Yayu, Determination of Convective Coefficient at the Outside Cover of a Monitor Greenhouse in Indonesia, Journal of Applied Sciences in Environmental Vol. 3, No1, pp. 37-46, 2008.
11
Businger, J. A., The glasshouse climate, In Physics of Plant Environment, Amsterdam, North-Holland, pp. 277-318, 1963.
12
Kittas, C., Katsoulas, N., Bartzanas, T., Boulard, T., and Mermier, M. Effect of vents' opening and insect screen on greenhouse ventilation, International Conference, Passive and Low Energy Cooling 59 for the Built Environment, pp. 59-64, 2005, Santorini, Greece.
13
Kittas, C., Boulard, T., and Papadakis, G., Natural ventilation of a greenhouse with ridge and side openings: sensitivity to temperature and wind effects, Transactions of the ASAE, Vol. 40, No.2, pp. 415-425.
14
Molina-Aiza, F. D., Valeraa, D. L., Peñaa, A. A., Gilb, J. A., and Lópeza, A., A study of natural ventilation in an Almería-type greenhouse with insect screens by means of tri-sonic anemometry. Biosystems Engineering. Vol. 104, Issue 2, 2009, pp. 224-242.
15
Guerrero, F. V., Murat, K., Efren, F. R., Raphael, L., Avraham, A., Chieri, K., and Gene, A. G., Developing a Control Strategy for Greenhouses Equipped with Natural Ventilation and Variable Pressure Fogging: Evapotranspiration Models and Simulated Comparion of Fixed and Variable Pressure Fog Cooling, 2010 ASABE Annual International Meeting, Paper Number: 1009388, 2010.
16
Teitel, M., Liran, O., Tanny, J., and Barak, M., Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate. Biosystems Engineering, Vol. 101, pp. 111-122, 2008.
17
Liu, S. Z., He, Y., Zhang, Y. B., and Miao, X. W., Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen, J Zhejiang Univ Sci B., Vol. 6, No. 6, pp. 523-529, 2005.
18
ASHRAE standard 41.6, RA 2006.
19
Jolliet, O., HORTITRANS. a model for predicting and optimizing humidity and transpiration in greenhouses. Journal of Agricultural Engineering Research 57, pp. 23-37, 1994.
20
The Korean Federation of Seeding Industries, http://hkyugmyo.or.kr/bbs/ board.php?bo_table=0001, Study group for plug seedling production. cafe.daum.net/plugseedling.
21
Nam, S. W., Application of Heat Balance Model to Design of Ventilating and Cooling Greenhouses. The Korean Society for Bio_Environment Control. Journal of environment Control, Vol.9 ,No.4, pp. 201-206. (2000) ISSN 1229-4675.
22
Handarto, M., Hayashi, E., Goto and Kozai, T Experimental Verification of Control Logic for Operation of a Fog Cooling System for a Naturally Ventilated Greenhouse. Environment Control in Biology, Vol. 45, No. 1, pp. 47-58, 2007.
23
Li, S. and Willitsa, D. H., Comparing low-pressure and high-pressure fogging systems in naturally ventilated greenhouses, Biosystems Engineering, Vol. 101, Issue. 1. pp. 69-77, 2008.
24
Jang, J. C., Kang, E. C., and Lee, E. J., Peak Cooling and Heating Load and Energy Simulation Study for a Special Greenhouse Facility, Journal of the Korean Solar Energy Society, pp. 72-76, 2009.
Information
  • Publisher :Korean Solar Energy Society
  • Publisher(Ko) :한국태양에너지학회
  • Journal Title :Journal of the Korean Solar Energy Society
  • Journal Title(Ko) :한국태양에너지학회 논문집
  • Volume : 36
  • No :5
  • Pages :31-50
  • Received Date : 2016-08-06
  • Accepted Date : 2016-10-10