Abstract
References
SunShot, Photovoltaic System Pricing Tren ds: Historical, Recent, and Near-Term Projections 2013 Edition, NREL, 2013. Bruno Andò, Senior Member, IEEE, Salvatore Baglio, Fellow, IEEE, Antonio Pistorio, Giuseppe Marco Tina, Member, IEEE, and Cristina Ventura. Sentinella: Smart Monitoring of Photovoltaic Systems at Panel Level, IEEE Transactions on Instrumentation and Measurement, Vol. 64, No. 8, 2015. Chine, W., Mellit, A., Lughi, V., Malek, A., Sulligoi, G., and Massi Pavan. A., A novel fault diagnosis technique for photovoltaic systems based on artificial neural networks, Renewable Energy 90, pp. 501-512, 2016. Chine, W., Mellit, A., Massi Pavan, A., and Kalogirou, S. A., Fault detection method for grid-connected photovoltaic plants, Renewable Energy 66, pp. 99-110, 2014. Pierluigi Guerriero, Fabio Di Napoli, Gianlorenzo Vallone, Vincenzo d’Alessandro and Santolo Daliento, Monitoring and Diagnostics of PV Plants by a Wireless Self-Powered Sensor for Individual Panels, IEEE Journal of Photovoltaics, Vol. 6, No. 1, 2016. So, J. H., Lim, H. M., Hwang, H. M., Jung, Y. S., Ko, S. W., and Ju, Y. C., Loss Calculation Method of Grid-Connected Photovoltaic System, Journal of the Korean Solar Energy Society, Vol. 33, No. 5, 2013. Ji, Y. G., Kong, J. H., Kang, G. H., Yu, G. J., Ahn, H. G, and Han, D. Y., The Characteristic of the Performance of the Bypass Diode with Composition Change of the String in Si-PV Module, Journal of Korea Institute of Electronics Engineers, Vol. 50, No. 7, pp. 985-996, 2014. Je, H. W. and Yang, O., Remote Monitoring System of Photovoltaic Inverter using Zigbee Communication, Journal of Advanced Information Technology and Convergence, Vol. 10, No. 2, 2012. Cho, H. C. and Sim, K. Y., A Development of Smart Monitoring Technique for Photovoltaic Power Systems, The Transactions of the Korean Institute of Electrical Engineers Vol. 64P, No. 2, pp. 50-56, 2015. Ji, P. S., Lee, J. P., Lee, D. J., Byeon, S. J., and Lim, J. Y., Monitoring System for Solar Cell of Photovoltaic Power Generation Using Zigbee Technique, Korea Institute of Electronics Engineers, pp. 17-19, 2011.
Information
- Publisher :Korean Solar Energy Society
- Publisher(Ko) :한국태양에너지학회
- Journal Title :Journal of the Korean Solar Energy Society
- Journal Title(Ko) :한국태양에너지학회 논문집
- Volume : 36
- No :5
- Pages :91-100
- Received Date : 2016-09-27
- Accepted Date : 2016-10-18
- DOI :https://doi.org/10.7836/kses.2016.36.5.091


Journal of the Korean Solar Energy Society







